Intent Execution Limitation without PA License
If PA license is not purchased, NetworkBrain assigns free license quota for trial to each feature. Each feature has a daily trial quota, and the trial quota for one feature cannot be used for another feature. Moreover, without PA license, the count of executed intents for each run in each feature is also limited.
No. |
Feature Category |
Features |
Daily Quota (Run Times) |
Intent
Count Limitation |
1 |
Interactive
Automation for troubleshooting |
Quick-Intent |
Free |
Maximum 24 intents |
Auto-Intent |
||||
Published Intents |
||||
Run Intent One by One (NI View, Map intent, Path Intent, Member Intent,
Golden Intent) |
||||
Run Intents within Runbook |
||||
Run intents within AI Bot |
||||
Schedule to Run Intent |
||||
Golden Check in Golden Intent Pane (run follow-up intents of the member intent) |
||||
2 |
Packaged
Intent Automation as |
Chatbot |
24 |
Maximum 24 intents |
Email-triggered
Diagnosis |
||||
Self-service
Diagnosis from Incident (IE + Portal) |
||||
Manual
Diagnosis from ServiceNow |
||||
3 |
Running
Automation for Network Assessment |
NIC
- Run Intents in Batch |
24 |
Maximum 24 intents |
ADT
- Run Intents Once |
0 |
Not available |
||
ADT
- Run Intents via Timer (PAF) |
0 |
Not Available |
||
4 |
Machine-to-Machine
running of Automation |
Intent-based Triggered
Automation |
24 |
Maximum
24 intents |
PAF
- Preventive Automation (Primary
Probe/LG Probe/Timer-triggered NIT/NIC/ADT) |
0 |
Not Available |
||
GES –Run Golden Intents Once |
0 |
Not available |
||
GES
–Run Intents via Timer |
0 |
Not
Available |
||
Note:
2. In the AI Bot,
"Maximum 24 intents" means users can execute up to 24 intents in
each question, which includes both home intents and follow-up intents. Users
can schedule run a maximum of 1 intent per question without PA license, or up to 12
intents per question with PA license. 3. For Chatbot, it is limited to 24 intents per run, but with in one Chatbot session, users can run intents for unlimited times. The PA License trial Quota allows for 24 runtimes per day and is deducted each time the Chatbot is opened, regardless of whether a diagnosis is performed through the Chatbot. |
Interactive Automation for troubleshooting
Limitations for Running Intents in Quick Intent, Auto Intent and Published Intent
Limitations for Running Intent One by One
Limitations for Running Intents within Runbook
When run intents in Runbook node, there is no runtime limitation. However, a maximum of 24 intents (including follow-up intents) can be executed each time one runbook node is executed.
Limitations for Running intents within AI Bot
For running intents within AI Bot, you can execute up to 24 intents in each question, which includes both home intents and follow-up intents. There is no free quota limitation. This logic applies to both interactively running intents and schedule run intents in AI Bot.
Limitations for Schedule to Run Intent
When schedule to run intents in NetworkBrain, there is no PA license free quota limitation. However, a maximum of 24 intents (including follow-up intents) can be executed for each schedule run.
Limitations for Running Intent to Perform Golden Check in Golden Intent Pane
When intents are run to perform golden check in Golden Intent Pane, there is no free quota limitation. However, a maximum of 24 intents can executed for each run.
Packaged Intent Automation as Interactive Service
Limitations for Running Intents in Chatbot
For Chatbot, the free PA license quota allows for 24 runtimes per day, and one runtime will be used each time the Chatbot is opened, regardless of whether a diagnosis is performed through the Chatbot.
Running intents in Email-triggered Diagnosis is limited by PA License free quota (24 runtimes per day), and you can only run a maximum of 24 intents for each run, including home intents and follow-up intents.
Running intents in Self-service Diagnosis from Incident is limited by PA License free quota (24 runtimes per day), and you can only run a maximum of 24 intents for each run, including home intents and follow-up intents.
Running intents in Manual Diagnosis from ServiceNow is limited by PA License free quota (24 runtimes per day), and you can only run a maximum of 24 intents for each run, including home intents and follow-up intents.
Running Automation for Network Assessment
Running intents in batch via NIC is limited by PA License free quota (24 runtimes per day), and you can only run a maximum of 24 intents for each run, including home intents and follow-up intents.
Limitations for Running ADT Intents (Once/Via Timer)
PA license does not provide free quota for running ADT intents by the "Run Intents Once" and "Run Intents via Timer" function (from ADT intent column menu). However, without PA License, you can run ADT intents in other scenarios, for instance, run ADT intents as follow-up diagnosis or schedule to run ADT intent.
Machine-to-Machine running of Automation
Limitations for Running Intents in TAF
Running intents trigged by TAF is limited by PA License free quota (24 runtimes per day), and a maximum of 24 intents for each run, including home intents and follow-up intents.
Limitations for PAF Installation
Defining and installing automation do not require PA license except for installing three types of probes (primary probe, Looking Glass probe, timer probe) to Preventive Automation (Trigger NIT / NIC / ADT Intents) as the Preventive Automation features has no free trial quota.
Limitations for Running Intents in Golden Engineering Studio
It is not allowed to run golden intent once in GES or run intents via timer in GES (Schedule tab) without PA license. No free quota is assigned for this.